Seem to have lost work on component failure modes
-- the derivation of -- bolocks.
This commit is contained in:
parent
8d009de6bd
commit
27f68c8f5b
@ -2,6 +2,6 @@ Write up detailed failure modes essay for R and OPAMP with ref to EN298, FMD-91,
|
||||
|
||||
Get thesis template, have emailed Aidian on this.
|
||||
|
||||
Start writing up approvals backgrouns to static FMEA.
|
||||
Start writing up approvals backgrounds to static FMEA.
|
||||
|
||||
|
||||
|
@ -74,7 +74,7 @@ Let us first define a component.
|
||||
%This is anything with which we use to build a product or system.
|
||||
This is anything we use to build a product or system.
|
||||
It could be something quite complicated
|
||||
like an integrated microcontroller, or quite simple like the humble resistor.
|
||||
like an integrated micro controller, or quite simple like the humble resistor.
|
||||
|
||||
We can define a
|
||||
component by its name, a manufacturers' part number and perhaps
|
||||
@ -160,7 +160,7 @@ Parameter change not considered for EN298 because the resistors are down-rated f
|
||||
maximum possible voltage exposure -- find refs.
|
||||
|
||||
|
||||
FMD-91 gives the following percentatges for failure rates in
|
||||
FMD-91 gives the following percentages for failure rates in
|
||||
\label{downrate}
|
||||
The parameter change, is usually a failure mode associated with over stressing the component.
|
||||
In a system designed to typical safety critical constraints (as in EN298)
|
||||
@ -171,7 +171,7 @@ these environmentally induced failure modes need not be considered.
|
||||
Literature suggests, latch up, latch down and oscillation.
|
||||
FMD-91 states, V+ disconnected, V- V+ shorted, NOOP and Low slew.
|
||||
|
||||
EN298 does not specifgically include OP_AMPS and these would fall under
|
||||
EN298 does not specifically define OP\_AMPS failure modes; these would fall under the procedure outlined in
|
||||
table \cite{en298}[A.1 note e].
|
||||
This demands that all open connections, and shorts between adjacent pins be considered.
|
||||
We can examine these failure modes by taking our 358 op-amp and examining
|
||||
@ -935,13 +935,14 @@ are added to UML diagram in figure \ref{fig:cfg} and represented in figure \ref
|
||||
|
||||
\begin{figure}[h]
|
||||
\centering
|
||||
\includegraphics[width=400pt,keepaspectratio=true]{../master_uml.jpg}
|
||||
\includegraphics[width=400pt,keepaspectratio=true]{master_uml.jpg}
|
||||
% cfg2.jpg: 702x464 pixel, 72dpi, 24.76x16.37 cm, bb=0 0 702 464
|
||||
\caption{Complete UML diagram}
|
||||
\label{fig:cfg2}
|
||||
\end{figure}
|
||||
|
||||
|
||||
|
||||
|
||||
\subsection{Ontological work on FMEA}
|
||||
|
||||
|