% Make the revision and doc number macro's then they are defined in one place
|
|
|
|
\ifthenelse {\boolean{paper}}
|
|
{
|
|
\begin{abstract}
|
|
A very abstract abstract
|
|
\end{abstract}
|
|
}
|
|
{
|
|
\section{Overvew}
|
|
}
|
|
|
|
\section{FMEA}
|
|
|
|
Two meanings, a general one Fault Mode Effects Analysis, meaning general statics diagnosis of a design, looking
|
|
at faults that can occur and their effect.
|
|
|
|
|
|
\subsection{Manufacturing Cost Reduction FMEA}
|
|
|
|
Second a methodology for reducing cost in manufacturing by taking fauls, their frequency
|
|
and their cost, multiplying these together, and then coming up with a priority list
|
|
for fixing knmown faults.
|
|
"The basics of FMEA by Robin E. McDermott et all"
|
|
ISBN 0-527-76320-9.
|
|
|
|
|
|
\subsection{Deterministic FMEA}
|
|
|
|
EN298 no two individual component failures may give rise to a dangerous condition.
|
|
|
|
\section{FMEDA Failure effect Mode Diagnositic Analysis}
|
|
|
|
This is a probablistic based methodology.
|
|
|
|
\subsection{Safe Failure Fraction}
|
|
|
|
Introduce the idea of coverage.
|
|
A good example is RAM in a microprocessor/microcontroller, we cann ot give 100i\% coverage to it.
|
|
We can perform some tests that give us 60\% coverage etc
|
|
|
|
\subsection{Diagnostic interval}
|
|
|
|
Reducing FIT with detecting a fraction of the faults within an interval. Give formulas etc
|
|
|
|
|
|
\subsection{Redundancy - Models}
|
|
|
|
1oo1 2oo3 etc
|
|
|
|
\subsection{Field Data}
|
|
|
|
OK for EN61508, not OK for nuclear industry find refs.
|
|
|
|
|
|
\section {FTA}
|
|
|
|
Fault tree Analysis
|
|
Show how it works, top down,
|
|
% read exita doc and ref it
|
|
|
|