Consider the FMEA type methodologies
|
|
where we look at all the failure modes in a system, and then
|
|
see how they can affect all other components within it,
|
|
to determine its system level symptom or failure mode.
|
|
We need to look at a large number of failure scenarios
|
|
to do this completely (all failure modes against all components).
|
|
This is represented in equation~\ref{eqn:fmea_state_exp},
|
|
where $N$ is the total number of components in the system, and
|
|
$cfm$ is the number of failure modes per component.
|
|
|
|
\begin{equation}
|
|
\label{eqn:fmea_state_exp}
|
|
N.(N-1).cfm % \\
|
|
%(N^2 - N).cfm
|
|
\end{equation}
|
|
|
|
|
|
The FMMD methodology breaks the analysis down into small stages,
|
|
by making the analyst choose functional groups, and then when analysed the groups
|
|
are treated as components to be used for a higher stage.
|
|
This is designed to address the state explosion (where $O$ is order
|
|
of complexity) $O=N^2$ inherent in equation~\ref{eqn:fmea_state_exp}.
|
|
|
|
\clearpage
|
|
|
|
We can view the functional groups in FMMD as forming a hierarchy.
|
|
If for the sake of example we consider each functional group to
|
|
be three components, figure~\ref{fig:three_tree} shows
|
|
how the levels work and converge to a top or system level.
|
|
|
|
\begin{figure}
|
|
\centering
|
|
\includegraphics[width=300pt]{./three_tree.png}
|
|
% three_tree.png: 780x226 pixel, 72dpi, 27.52x7.97 cm, bb=0 0 780 226
|
|
\caption{Functional Group Tree example}
|
|
\label{fig:three_tree}
|
|
\end{figure}
|
|
|
|
\clearpage
|
|
We can represent the number of failure scenarios to check in an FMMD hierarchy
|
|
with equation~\ref{eqn:anscen}.
|
|
|
|
\begin{equation}
|
|
\label{eqn:anscen}
|
|
\sum_{n=0}^{L} {fgn}^{n}.fgn.cfm.(fgn-1)
|
|
\end{equation}
|
|
|
|
Where $fgn$ is the number of components in each functional group,
|
|
and $cfm$ is the number of failure modes per component
|
|
and L is the number of levels, the number of
|
|
analysis scenarios to consider is show in equation~\ref{eqn:anscen}.
|
|
|
|
|
|
So for a very simple analysis with three components forming a functional group where
|
|
each component has three failure modes, we have only one level (zero'th).
|
|
So to check every failure modes against the other components in the functional group
|
|
requires 18 checks.
|
|
|
|
\begin{equation}
|
|
\label{eqn:anscen2}
|
|
\sum_{n=0}^{0} {3}^{0}.3.3.(3-1) = 18
|
|
\end{equation}
|
|
\clearpage
|
|
|
|
|
|
|
|
In other words, we have three components in our functional group,
|
|
and nine failure modes to consider.
|
|
So taking each failure mode and looking at how that could affect the functional group,
|
|
we must compare each failure mode against the two other components (the `$fgn-1$' term).
|
|
|
|
For the one `zero' level FMMD case we are doing the same thing as FMEA type analysis
|
|
(but on a very simple small sub-system).
|
|
We are looking at how each failure~mode can effect the system/top level.
|
|
We can use equation~\ref{eqn:fmea_state_exp} to represent
|
|
the number of checks to rigorously perform FMEA, where $N$ is the total
|
|
number of components in the system, and $cfm$ is the number of failures per component.
|
|
|
|
|
|
|
|
Where $N=3$ and $cfm=3$ we can see that the number of checks for this simple functional
|
|
group is the same for equation~\ref{eqn:fmea_state_exp}
|
|
and equation~\ref{eqn:anscen}.
|
|
\clearpage
|
|
|
|
\section{Example}
|
|
|
|
To see the effects of reducing `state~explosion' we need to look at a larger system.
|
|
Let us take a system with 3 levels and apply these formulae.
|
|
Having three levels (in addition to the top zero'th level)
|
|
will require 81 base level components.
|
|
|
|
$$
|
|
%\begin{equation}
|
|
\label{eqn:fmea_state_exp}
|
|
81.(81-1).3 = 19440 % \\
|
|
%(N^2 - N).cfm
|
|
%\end{equation}
|
|
$$
|
|
|
|
$$
|
|
%\begin{equation}
|
|
% \label{eqn:anscen}
|
|
\sum_{n=0}^{3} {3}^{n}.3.3.(2) = 720
|
|
%\end{equation}
|
|
$$
|
|
|
|
Thus for FMMD we needed to examine 720 failure mode scenarios, and for traditional FMEA
|
|
type analysis methods 19440.
|
|
% In practical example followed through, no more than 9 components have ever been required for a functional
|
|
% group and the largest known number of failure modes has been 6.
|
|
% If we take these numbers and double them (18 components per functional group
|
|
% and 12 failure modes per component) and apply the formulas for a 4 level analysis
|
|
% (i.e.
|
|
|
|
\clearpage
|
|
Note that for all possible double simultaneous failures the equation~\ref{eqn:fmea_state_exp} becomes
|
|
equation~\ref{eqn:fmea_state_exp2} essentially making the order $N^3$.
|
|
The FMMD case (equation~\ref{eqn:anscen2}), is cubic within the functional groups only,
|
|
not all the components in the system.
|
|
|
|
|
|
\begin{equation}
|
|
\label{eqn:fmea_state_exp2}
|
|
N.(N-1).(N-2).cfm % \\
|
|
%(N^2 - N).cfm
|
|
\end{equation}
|
|
|
|
\begin{equation}
|
|
\label{eqn:anscen2}
|
|
\sum_{n=0}^{L} {fgn}^{n}.fgn.cfm.(fgn-1).(fgn-2)
|
|
\end{equation}
|
|
|
|
|
|