diff --git a/old_thesis/opamp_circuits_C_GARRETT/opamps.tex b/old_thesis/opamp_circuits_C_GARRETT/opamps.tex index 73fe465..c2a04a1 100644 --- a/old_thesis/opamp_circuits_C_GARRETT/opamps.tex +++ b/old_thesis/opamp_circuits_C_GARRETT/opamps.tex @@ -41,6 +41,7 @@ Function $fm$ applied to a component returns its failure modes. The circuits specified are not typical safety critical circuitry which usually has both redundancy and self~checking and/or diagnostic features build in. These are examples of the FMMD methodology being applied to some standard electronic circuits. +\today \end{abstract} \maketitle \tableofcontents @@ -892,7 +893,7 @@ We can now form a {\fg} from the OPAMP and the $INVPD$ \textbf{Failure Scenario} & & \textbf{Inverted Amp Effect} & & \textbf{Symptom} \\ \hline \hline FS1: INVPD LOW & & NEGATIVE - input & & $ HIGH $ \\ - FS2: INVPD HIGH & & Positive - input & & $ LOW $ + FS2: INVPD HIGH & & Positive - input & & $ LOW $ \\ FS5: AMP L\_DN & & $ INVAMP_{low} $ & & $ LOW $ \\ \hline