@ -5,7 +5,18 @@ paper
|
||||
describes how the FMMD methodology can be used to refine
|
||||
safety critical designs and identify undetectable and dormant faults.
|
||||
%
|
||||
Once undetecable faults or dormant faults are discovered
|
||||
Its uses an industry standard mill-volt amplifier
|
||||
circuit, intended for reading thermocouples.
|
||||
It has an inbuilt safety resistor which allows it
|
||||
to detect the thermocouple becoming disconnected/going OPEN.
|
||||
%
|
||||
This circuit is analysed from an FMMD perspective and
|
||||
and two undetectable failure modes are identified.
|
||||
A `safety check' circuit is then proposed and analysed.
|
||||
This has no undetectable failure modes, but does have one
|
||||
`dormant' failure mode.
|
||||
%
|
||||
This paper shows that once undetectable faults or dormant faults are discovered
|
||||
the design can be altered (or have a safety component added), and the FMMD analysis process re-applied.
|
||||
This can be an iterative process applied until the
|
||||
design has an acceptable level safety. % of dormant or undetectable failure modes.
|
||||
@ -21,14 +32,26 @@ This chapter
|
||||
describes how the FMMD methodology can be used to examine
|
||||
safety critical designs and identify undetectable and dormant faults.
|
||||
%
|
||||
Once undetecable faults or dormant faults are discovered
|
||||
Its uses an industry standard mill-volt amplifier
|
||||
circuit, intended for reading thermocouples.
|
||||
It has an inbuilt safety resistor which allows it
|
||||
to detect the thermocouple becoming disconnected/going OPEN.
|
||||
%
|
||||
This circuit is analysed from an FMMD perspective and
|
||||
and two undetectable failure modes are identified.
|
||||
A `safety check' circuit is then proposed and analysed.
|
||||
This has no undetectable failure modes, but does have one
|
||||
`dormant' failure mode.
|
||||
%
|
||||
This paper shows that once undetectable faults or dormant faults are discovered
|
||||
the design can be altered (or have a safety component added), and the FMMD analysis process re-applied.
|
||||
This can be an iterative process which can be applied until the
|
||||
design has an acceptable level of safety. % dormant or undetectable failure modes.
|
||||
This can be an iterative process applied until the
|
||||
design has an acceptable level safety. % of dormant or undetectable failure modes.
|
||||
%
|
||||
Used in this way, its is a design aide, giving the user
|
||||
the possibility to refine/correct a {\dc} from the perspective
|
||||
of its failure mode behaviour.
|
||||
|
||||
}
|
||||
|
||||
|
||||
@ -44,9 +67,18 @@ the failure mode behaviour is then viewed from the
|
||||
{\fg} perspective (i.e. as a symptoms of the {\fg}) and
|
||||
common symptoms are then collected. The final stage
|
||||
is to create a {\dc} which has the symptoms of the {\fg}
|
||||
it was sourced from, as its failure modes.
|
||||
it was sourced from, as its failure modes.
|
||||
%
|
||||
%From the failure mode behaviour of the {\fg} common symptoms are collected.
|
||||
These common symptoms are % in effect
|
||||
the failure mode behaviour of
|
||||
the {\fg} viewed as an % single
|
||||
entity, or a `black box' component.
|
||||
%
|
||||
From the analysis of the {\fg} we can create a {\dc}, where the failure modes
|
||||
are the symptoms of the {\fg} we derived it from.
|
||||
}
|
||||
|
||||
{
|
||||
\paragraph{Overview of FMMD Methodology}
|
||||
To re-cap from chapter \ref{symptomex},
|
||||
the principle of FMMD analysis is a five stage process,
|
||||
@ -57,9 +89,6 @@ the failure mode behaviour is then viewed from the
|
||||
common symptoms are then collected. The final stage
|
||||
is to create a {\dc} which has the symptoms of the {\fg}
|
||||
it was sourced from, as its failure modes.
|
||||
|
||||
{
|
||||
|
||||
%
|
||||
%From the failure mode behaviour of the {\fg} common symptoms are collected.
|
||||
These common symptoms are % in effect
|
||||
@ -69,37 +98,51 @@ entity, or a `black box' component.
|
||||
%
|
||||
From the analysis of the {\fg} we can create a {\dc}, where the failure modes
|
||||
are the symptoms of the {\fg} we derived it from.
|
||||
}
|
||||
%
|
||||
\paragraph{detectable and undetectable failure modes}
|
||||
\paragraph{Undetectable failure modes.}
|
||||
The symptoms will be detectable (like a value out of range)
|
||||
or undetectable (like a logic state or value being incorrect).
|
||||
The `undetectable' failure modes undertsandably, are the most worrying for the safety critical designer.
|
||||
EN61058, the statistically based European Norm, using ratios
|
||||
The `undetectable' failure modes understandably, are the most worrying for the safety critical designer.
|
||||
EN61058~\cite{en61508}, the statistically based failure mode European Norm, using ratios
|
||||
of detected and undetected system failure modes to
|
||||
classify the sytems safety levels and describes sub-clasifications
|
||||
for detected and undetected failure modes~\cite{en61508}.
|
||||
classify the systems safety levels and describes sub-clasifications
|
||||
for detected and undetected failure modes.
|
||||
%\gloss{DU}
|
||||
%\gloss{DD}
|
||||
|
||||
%It is these that are, generally the ones that stand out as single
|
||||
%failure modes.
|
||||
For instance, out of range values, are easy to detect by
|
||||
systems using the {\dc} supplying them.
|
||||
Undetectable faults are ones that forward incorrect information
|
||||
where we have no way of validating or testing it.
|
||||
Undetectable faults are ones that supply incorrect information or states
|
||||
where we have no way of knowing whether they are correct or not.
|
||||
% we know we can cope with; they
|
||||
%are an obvious error condition that will be detected by any modules
|
||||
%using the {\dc}.
|
||||
%
|
||||
An undetecable failure mode can introduce serious
|
||||
Undetectable failure modes can introduce serious
|
||||
errors into a SYSTEM.
|
||||
|
||||
|
||||
|
||||
\paragraph{dormant faults} A dormant fault is one
|
||||
which can manifest its-self in conjuction with
|
||||
\paragraph{Dormant faults.}
|
||||
A dormant fault is one
|
||||
which can manifest its-self in conjunction with
|
||||
another failure mode becoming active, or an environmental
|
||||
condition changing (for instance temperature). Some
|
||||
condition changing (for instance temperature).
|
||||
Some
|
||||
component failure modes may lead to dormant failure modes.
|
||||
By examining test cases from a functional group against all
|
||||
For instance a transistor failing OPEN when it is meant
|
||||
to be in an OFF state would be a dormant fault.
|
||||
Even though the fault is active, the transistor
|
||||
is, for the time being, behaving correctly.
|
||||
%
|
||||
If we examine the circuit from both operational states,
|
||||
i.e. the transistor when is is both meant to be ON and OFF
|
||||
we can determine all the consequences of that particular failure.
|
||||
%
|
||||
More generally, by examining test cases from a functional group against all
|
||||
operational states and germane environmental conditions
|
||||
we can determine all the failure modes of the {\fg}.
|
||||
|
||||
@ -143,7 +186,7 @@ We then analsye the {\fg} and the resultant {\dc} failure modes/symptoms are dis
|
||||
|
||||
This circuit amplifies a milli-volt input by a gain of $\approx$ 184 ($\frac{150E3}{820}+1$)
|
||||
\footnote{The resistors used to program the gain of the op-amp would typically be of a $ \le 1\%$ guaranteed
|
||||
tolerance. In practise, the small variations would be corrected with software constants prorgammed during production
|
||||
tolerance. In practise, the small variations would be corrected with software constants programmed during production
|
||||
test/calibration.}.
|
||||
An offset is applied to the input by R18 and R22 forming a potential divider
|
||||
of $\frac{820}{2.2E6+820}$. With 5V applied as Vcc this gives an input offset of $1.86\,mV$.
|
||||
@ -153,7 +196,7 @@ So the amplified offset is $\approx 342 \, mV$.
|
||||
We can determine the output of the amplifier
|
||||
by subtracting this amount from the reading. We can also define an acceptable
|
||||
range for the readings. This would depend on the characteristics of milli-volt source, and also on the
|
||||
thresholds of the volatges considered out of range. For the sake of example let us
|
||||
thresholds of the voltages considered out of range. For the sake of example let us
|
||||
consider this to be a type K thermocouple amplifier, with a range of temperatures
|
||||
expected to be within {{0}\oc} and {{300}\oc}.
|
||||
|
||||
@ -162,8 +205,8 @@ Choosing the common Nickel-Chromium v. Nickel Aluminium `K' type thermocouple,
|
||||
{{0}\oc} provides an EMF of 0mV, and {{300}\oc} 12.207.
|
||||
Multiplying these by 184 and adding the 1.86mV offset gives
|
||||
342.24mV and 2563.12mV. This is now in a suitable range to be read by
|
||||
an analogue didtital converter, which will have a voltage span
|
||||
typically between 3.3V and 5V on modern microcontrollers/ADC (Analogue Digital Converter) chips.
|
||||
an analogue digital converter, which will have a voltage span
|
||||
typically between 3.3V and 5V on modern micro-controllers/ADC (Analogue Digital Converter) chips.
|
||||
Note that this also leaves a margin or error on both sides of the range.
|
||||
If the thermocouple were to become colder than {{0}\oc} it would supply
|
||||
a negative voltage, which would subtract from the offset.
|
||||
@ -242,7 +285,7 @@ this may be unacceptable.
|
||||
We will need to add some type of detection mechanism to the circuit to
|
||||
test $R_{off}$ periodically.
|
||||
For instance were we to check $R_off$ every $\tau = 20mS$ work out detection
|
||||
allowance according to EN61508.
|
||||
allowance according to EN61508~\cite{en61508}.
|
||||
|
||||
|
||||
\section{Proposed Checking Method}
|
||||
@ -320,13 +363,13 @@ and the reading is assumed to be valid.
|
||||
\hline
|
||||
\hline
|
||||
%% OK TR1 OFF , and so 36 in series. R36 has shorted so
|
||||
$\overline{TEST\_LINE}$ ON & TC:1 $R36$ SHORT & No added resistance & NO TEST EFFECT & XX 1.38 \\ \hline
|
||||
$\overline{TEST\_LINE}$ ON & TC:1 $R36$ SHORT & No added resistance & NO TEST EFFECT & 1.38 \\ \hline
|
||||
%%
|
||||
$\overline{TEST\_LINE}$ OFF & TC:1 $R36$ SHORT & dormant failure & NO SYMPTOM & XX 1.38 \\ \hline
|
||||
$\overline{TEST\_LINE}$ OFF & TC:1 $R36$ SHORT & dormant failure & NO SYMPTOM & 1.38 \\ \hline
|
||||
%% here TR1 should be OFF, as R36 is open we now have an open circuit
|
||||
$\overline{TEST\_LINE}$ ON & TC:2 $R36$ OPEN & open circuit & OPEN CIRCUIT & XX 12.42\\ \hline
|
||||
$\overline{TEST\_LINE}$ ON & TC:2 $R36$ OPEN & open circuit & OPEN CIRCUIT & 12.42\\ \hline
|
||||
%% here TR1 should be ON and R36 by-passed, the fact it has gone OPEN means no symptom here, a dormant failure.
|
||||
$\overline{TEST\_LINE}$ OFF & TC:2 $R36$ OPEN & dormant failure & NO SYMPTOM & XX 12.42\\ \hline
|
||||
$\overline{TEST\_LINE}$ OFF & TC:2 $R36$ OPEN & dormant failure & NO SYMPTOM & 12.42\\ \hline
|
||||
\hline
|
||||
%
|
||||
%% TR1 OFF so R36 should be in series. Because TR1 is ON because it is faulty, R36 is not in series
|
||||
@ -336,10 +379,10 @@ $\overline{TEST\_LINE}$ LINE ON & TC:3 $TR1$ ALWAYS ON & No added resista
|
||||
$\overline{TEST\_LINE}$ OFF & TC:3 $TR1$ ALWAYS ON & dormant failure & NO SYMPTOM & XX 1.38 \\ \hline
|
||||
%%
|
||||
%% TR1 should be off as overline{TEST\_LINE}$ is ON. As TR1 is faulty it is always off and we have a dormant failure.
|
||||
$\overline{TEST\_LINE}$ LINE ON & TC:4 $TR1$ ALWAYS OFF & dormant failure & NO SYMPTOM & XX 1.38 \\ \hline
|
||||
$\overline{TEST\_LINE}$ LINE ON & TC:4 $TR1$ ALWAYS OFF & dormant failure & NO SYMPTOM & 1.38 \\ \hline
|
||||
%%
|
||||
%% TR1 should be ON, but is off due to TR1 failure. The resistance R36 will always be in series therefore
|
||||
$\overline{TEST\_LINE}$ OFF & TC:4 $TR1$ ALWAYS OFF & resistance always added & NO TEST EFFECT & XX 1.38 \\ \hline
|
||||
$\overline{TEST\_LINE}$ OFF & TC:4 $TR1$ ALWAYS OFF & resistance always added & NO TEST EFFECT & 1.38 \\ \hline
|
||||
\hline
|
||||
\end{tabular}
|
||||
\label{tab:testaddition}
|
||||
@ -543,7 +586,7 @@ The meanings of and values assigned to its co-efficients are described in table
|
||||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
||||
|
||||
Taking these parameters and applying equation \ref{microcircuitfit},
|
||||
$$ 0.04 \times1.4 \times0.0026 \times2.0 \times2.0 \times1.0 = .0005824 $$
|
||||
$$ 0.04 \times 1.4 \times 0.0026 \times 2.0 \times 2.0 \times 1.0 = .0005824 $$
|
||||
we get a value of $0.0005824 \times {10}^6$ failures per hour.
|
||||
This is a worst case FIT\footnote{where FIT (Failure in Time) is defined as
|
||||
failures per Billion (${10}^9$) hours of operation} of 1.
|
||||
@ -551,7 +594,8 @@ failures per Billion (${10}^9$) hours of operation} of 1.
|
||||
\subsection{Switching Transistor}
|
||||
|
||||
The switching transistor will be operating at a low frequency
|
||||
and well within 50\% of its maximum voltage.
|
||||
and well within 50\% of its maximum voltage. We can also assume a benign
|
||||
temperature environment of $ < 60^{o}C$.
|
||||
MIL-HDBK-217F\cite{mil1992}[6-25] gives an exmaple
|
||||
transistor in these environmental conditions, and assigns an FIT value of 11.
|
||||
|
||||
@ -572,7 +616,7 @@ but statistically less reliable.
|
||||
\paragraph{Practical side effect of checking for thermocouple disconnection}
|
||||
|
||||
Because the potential divider provides an offset as a side effect of detecting a disconnection
|
||||
resistance in the thermocopule extension or compensation cable will have an effect.
|
||||
resistance in the thermocouple extension or compensation cable will have an effect.
|
||||
For a `k' type thermocouple this would be of the order of $0.5 { }^{o}C$ for $10\Omega$ of
|
||||
cable loop impedance. Therefore, accuracy constraints and cable impedance should be considered
|
||||
to determine specified maximum compensation/extension lengths.
|
||||
|
@ -636,7 +636,7 @@ A technique of modularising, or breaking down the problem is clearly necessary.
|
||||
|
||||
One question that anyone developing a safety critical analysis design tool
|
||||
could do well to answer, is how the methodology would cope with known previous disasters.
|
||||
The Challenger disaster is a good example, and was well documented and investigated.
|
||||
The Challenger disaster is a good example, and was well documented and investigated~\cite{challenger}.
|
||||
|
||||
The problem lay in a seal that had an operating temperature range.
|
||||
On the day of the launch the temperature of this seal was out of range.
|
||||
|
@ -741,7 +741,7 @@ Contour $C$ is \textbf{enclosed} by contour $A$. This says
|
||||
that for failure~mode $C$ to occur failure mode $A$
|
||||
must have occurred.
|
||||
A famous example of this is the space shuttle `O' ring failure that
|
||||
caused the 1986 Challenger disaster\cite{wdycwopt}.
|
||||
caused the 1986 Challenger disaster~\cite{challenger}~\cite{wdycwopt}.
|
||||
For the failure mode to occur, the ambient temperature had to
|
||||
be below a critical value.
|
||||
If we take the failure mode of the `O' ring to be $C$
|
||||
|
@ -305,6 +305,13 @@
|
||||
year = "1994"
|
||||
}
|
||||
|
||||
@MISC{challenger,
|
||||
author = "U.S. Presidential Commission",
|
||||
title = "Report of the SpaceShuttle Challanger Accident",
|
||||
howpublished = "Available from http://science.ksc.nasa.gov/shuttle/missions/51-l/docs/rogers-commission/table-of-contents.html",
|
||||
year = "1986"
|
||||
}
|
||||
|
||||
@MISC{en61508,
|
||||
author = "E N Standard",
|
||||
title = "EN61508:2002 Functional safety of electrical/electronic/programmable electronic safety related systems",
|
||||
@ -425,7 +432,7 @@ OPTissn = {},
|
||||
|
||||
|
||||
@TechReport{eurothermtables,
|
||||
author = {Alan Brown},
|
||||
author = {Eurotherm Ltd.},
|
||||
title = {Thermocouple Emf TABLES and PLATINUM 100 RESISTANCE THERMOMETER TABLES},
|
||||
institution = {Eurotherm, UK},
|
||||
year = {1973},
|
||||
|
Loading…
Reference in New Issue
Block a user