@ -1932,6 +1932,8 @@ take the mean square error of these accuracy figures.
|
||||
|
||||
\paragraph{Single Fault FMEA Analysis \\ of PT100 Four wire circuit}
|
||||
|
||||
|
||||
\ifthenelse {\boolean{pld}}
|
||||
\paragraph{Single Fault Modes as PLD}
|
||||
|
||||
The component~failure~modes in table \ref{ptfmea} can be represented as contours
|
||||
@ -1939,11 +1941,7 @@ on a PLD diagram.
|
||||
Each test case, is defined by the contours that enclose
|
||||
it. The test cases here deal with single faults only
|
||||
and are thus enclosed by one contour each.
|
||||
|
||||
|
||||
\fmodegloss
|
||||
|
||||
|
||||
\begin{figure}[h]
|
||||
\centering
|
||||
\includegraphics[width=400pt,bb=0 0 518 365,keepaspectratio=true]{./CH5_Examples/pt100_tc.png}
|
||||
@ -1951,6 +1949,7 @@ and are thus enclosed by one contour each.
|
||||
\caption{PT100 Component Failure Modes}
|
||||
\label{fig:pt100_tc}
|
||||
\end{figure}
|
||||
} % \ifthenelse {\boolean{pld}}
|
||||
|
||||
%ating input Fault
|
||||
This circuit supplies two results, the {\em sense+} and {\em sense-} voltage readings.
|
||||
@ -1959,21 +1958,7 @@ valid temperature range for this example ({0\oc} .. {300\oc}) we can calculate
|
||||
valid voltage reading ranges by using the standard voltage divider equation \ref{eqn:vd}
|
||||
for the circuit shown in figure \ref{fig:vd}.
|
||||
|
||||
%
|
||||
%\begin{figure}[h]
|
||||
% \centering
|
||||
% \includegraphics[width=100pt,bb=0 0 183 170,keepaspectratio=true]{./pt100/voltage_divider.png}
|
||||
% % voltage_divider.png: 183x170 pixel, 72dpi, 6.46x6.00 cm, bb=0 0 183 170
|
||||
% \caption{Voltage Divider}
|
||||
% \label{fig:vd}
|
||||
%\end{figure}
|
||||
%%The looking at figure \ref{fig:vd} the standard voltage divider formula (equation \ref{eqn:vd}) is used.
|
||||
%
|
||||
%\begin{equation}
|
||||
%\label{eqn:vd}
|
||||
% V_{out} = V_{in}.\frac{Z2}{Z2+Z1}
|
||||
%\end{equation}
|
||||
%
|
||||
|
||||
|
||||
|
||||
\paragraph{Proof of Out of Range \\ Values for Failures}
|
||||
@ -2232,7 +2217,7 @@ The FIT for the circuit as a whole is the sum of MTTF values for all the
|
||||
test cases. The PT100 circuit here has a FIT of 342.6. This is a MTTF of
|
||||
about 360 years per circuit.
|
||||
|
||||
A Probablistic tree can now be drawn, with a FIT value for the PT100
|
||||
A probabilistic tree can now be drawn, with a FIT value for the PT100
|
||||
circuit and FIT values for all the component fault modes that it was calculated from.
|
||||
We can see from this that that the most likely fault is the thermistor going OPEN.
|
||||
This circuit is around 10 times more likely to fail in this way than in any other.
|
||||
@ -2458,6 +2443,8 @@ This shorts the sense+ and sense- to Vcc.
|
||||
Both values will be out of range.
|
||||
|
||||
\clearpage
|
||||
|
||||
|
||||
\subsection{Double Faults Represented on a PLD Diagram}
|
||||
|
||||
We can show the test cases on a diagram with the double faults residing on regions
|
||||
@ -2487,11 +2474,13 @@ In all the test case results we have at least one out of range value, except for
|
||||
$TC\_7$
|
||||
which has two unknown values/floating readings. We can collect all the faults, except $TC\_7$,
|
||||
into the symptom $OUT\_OF\_RANGE$.
|
||||
As a symptom $TC\_7$ could be described as $FLOATING$. We can thus draw a PLD diagram representing the
|
||||
As a symptom $TC\_7$ could be described as $FLOATING$.
|
||||
|
||||
\ifthenelse {\boolean{pld}}
|
||||
We can thus draw a PLD diagram representing the
|
||||
failure modes of this functional~group, the pt100 circuit from the perspective of double simultaneous failures,
|
||||
in figure \ref{fig:pt100_doublef}.
|
||||
|
||||
|
||||
\begin{figure}[h]
|
||||
\centering
|
||||
\includegraphics[width=450pt,bb=0 0 730 641,keepaspectratio=true]{./CH5_Examples/plddoublesymptom.png}
|
||||
@ -2499,14 +2488,15 @@ in figure \ref{fig:pt100_doublef}.
|
||||
\caption{PT100 Double Simultaneous Faults}
|
||||
\label{fig:plddoublesymptom}
|
||||
\end{figure}
|
||||
|
||||
} %% \ifthenelse {\boolean{pld}}
|
||||
|
||||
\clearpage
|
||||
\subsection{Derived Component : The PT100 Circuit}
|
||||
The PT100 circuit again, can now be treated as a component in its own right, and has two failure modes,
|
||||
{\textbf{OUT\_OF\_RANGE}} and {\textbf{FLOATING}}.
|
||||
It can now be represented as a PLD see figure \ref{fig:pt100_doublef}.
|
||||
|
||||
\ifthenelse {\boolean{pld}}
|
||||
It can now be represented as a PLD see figure \ref{fig:pt100_doublef}.
|
||||
\begin{figure}[h]
|
||||
\centering
|
||||
\includegraphics[width=100pt,bb=0 0 167 194,keepaspectratio=true]{./CH5_Examples/pt100_doublef.png}
|
||||
@ -2514,6 +2504,8 @@ It can now be represented as a PLD see figure \ref{fig:pt100_doublef}.
|
||||
\caption{PT100 Circuit Failure Modes : From Double Faults Analysis}
|
||||
\label{fig:pt100_doublef}
|
||||
\end{figure}
|
||||
} % \ifthenelse {\boolean{pld}}
|
||||
|
||||
|
||||
\subsection{Statistics}
|
||||
|
||||
|