@ -677,7 +677,7 @@ TC 12: & $R_1$ SHORT $R_2$ SHORT & high & low & Both out of ran
|
|||||||
TC 14: & $R_1$ SHORT $R_3$ SHORT & high & high & Both out of range \\ \hline
|
TC 14: & $R_1$ SHORT $R_3$ SHORT & high & high & Both out of range \\ \hline
|
||||||
|
|
||||||
\hline
|
\hline
|
||||||
TC 15: & $R_2$ OPEN $R_3$ SHORT & high & Floating input Fault & sense+ out of range \\ \hline
|
TC 15: & $R_2$ OPEN $R_3$ OPEN & high & Floating input Fault & sense+ out of range \\ \hline
|
||||||
TC 16: & $R_2$ OPEN $R_3$ SHORT & high & high & Both out of Range \\ \hline
|
TC 16: & $R_2$ OPEN $R_3$ SHORT & high & high & Both out of Range \\ \hline
|
||||||
TC 17: & $R_2$ SHORT $R_3$ OPEN & high & low & Both out of Range \\ \hline
|
TC 17: & $R_2$ SHORT $R_3$ OPEN & high & low & Both out of Range \\ \hline
|
||||||
TC 18: & $R_2$ SHORT $R_3$ SHORT & low & low & Both out of Range \\ \hline
|
TC 18: & $R_2$ SHORT $R_3$ SHORT & low & low & Both out of Range \\ \hline
|
||||||
@ -864,13 +864,13 @@ a given cardinality constraint is not visually obvious.
|
|||||||
\subsubsection{Symptom Extraction}
|
\subsubsection{Symptom Extraction}
|
||||||
|
|
||||||
We can now examine the results of the test case analysis and apply symptom abstraction.
|
We can now examine the results of the test case analysis and apply symptom abstraction.
|
||||||
In all the test case results we have at least one an out of range value, except for
|
In all the test case results we have at least one out of range value, except for
|
||||||
$TC\_7$
|
$TC\_7$
|
||||||
which has two unknown values/floating readings. We can collect all the faults, except $TC\_7$,
|
which has two unknown values/floating readings. We can collect all the faults, except $TC\_7$,
|
||||||
into the symptom $OUT\_OF\_RANGE$.
|
into the symptom $OUT\_OF\_RANGE$.
|
||||||
As a symptom $TC\_7$ could be described as $FLOATING$. We can thus draw a PLD diagram representing the
|
As a symptom $TC\_7$ could be described as $FLOATING$. We can thus draw a PLD diagram representing the
|
||||||
failure modes of this functional~group, the pt100 circuit from the perspective of double simultaneous failures,
|
failure modes of this functional~group, the pt100 circuit from the perspective of double simultaneous failures,
|
||||||
in figure \ref{fig:dubsim}.
|
in figure \ref{fig:pt100_doublef}.
|
||||||
|
|
||||||
|
|
||||||