more on FMEDA
This commit is contained in:
parent
b2eb249c95
commit
a06d136ee4
@ -352,14 +352,53 @@ against all safe and dangerous failure probabilities.
|
||||
Again this is usually expressed as a percentage.
|
||||
|
||||
$$ SFF = \big( \Sigma\lambda_S + \Sigma\lambda_{DD} \big) / \big( \Sigma\lambda_S + \Sigma\lambda_D \big) $$
|
||||
SFF determines how proportionately fail-safe a system is, not how reliable it is !
|
||||
|
||||
\end{frame}
|
||||
|
||||
\begin{frame}
|
||||
\frametitle{ FMEDA - Failure Modes Effects and Diagnostic Analysis}
|
||||
SIL Levels are how they are calculated
|
||||
To achieve SIL levels, diagnostic coverage and SFF levels are prescribed along with
|
||||
hardware architectures and software techniques.
|
||||
Over all the aim of SIL is classify the safety of a system,
|
||||
by statistically determining how frequently it can fail dangerously.
|
||||
|
||||
|
||||
\end{frame}
|
||||
|
||||
\begin{frame}
|
||||
\frametitle{ FMEDA - Failure Modes Effects and Diagnostic Analysis}
|
||||
{
|
||||
\begin{table}[ht]
|
||||
\caption{FMEA Calculations} % title of Table
|
||||
%\centering % used for centering table
|
||||
\begin{tabular}{|| l | l | c | c | l ||} \hline
|
||||
\textbf{SIL} & \textbf{Low Demand} & \textbf{Continuous Demand} \\
|
||||
& Prob of failing on demand & Prob of failure per hour \\ \hline \hline
|
||||
4 & $ 10^{-5}$ to $< 10^{-4}$ & $ 10^{-9}$ to $< 10^{-8}$ \\ \hline
|
||||
3 & $ 10^{-4}$ to $< 10^{-3}$ & $ 10^{-8}$ to $< 10^{-7}$ \\ \hline
|
||||
2 & $ 10^{-3}$ to $< 10^{-2}$ & $ 10^{-7}$ to $< 10^{-6}$ \\ \hline
|
||||
1 & $ 10^{-2}$ to $< 10^{-1}$ & $ 10^{-6}$ to $< 10^{-5}$ \\ \hline
|
||||
|
||||
\hline
|
||||
\end{tabular}
|
||||
\end{table}
|
||||
}
|
||||
Table adapted from EN61508-1:2001 [7.6.2.9 p33]
|
||||
\end{frame}
|
||||
|
||||
\begin{frame}
|
||||
\frametitle{ FMEDA - Failure Modes Effects and Diagnostic Analysis}
|
||||
FMEDA is a modern extension of FMEA, in that it will allow for
|
||||
self checking features, and provides detailed recommendations for computer/software architecture.
|
||||
It also has a simple final result, a Safety Integrity Level (SIL) from 1 to 4 (where 4 is safest).
|
||||
|
||||
FMEA can be used as a term simple to mean Failure Mode Effects Analysis, and is
|
||||
part of product approval for many regulated products in the EU and the USA...
|
||||
|
||||
\end{frame}
|
||||
|
||||
|
||||
|
||||
|
||||
\section{FMEA used for Safety Critical Approvals}
|
||||
@ -410,9 +449,7 @@ judged to be in critical sections of the product.
|
||||
\pause \item FMEA type methodologies were designed for simple electro-mechanical systems of the 1940's to 1960's.
|
||||
\end{itemize}
|
||||
|
||||
%FMEDA is a modern extension of FMEA, in that it will allow for
|
||||
%self checking features, and provides detailed recommendations for computer/software architecture,
|
||||
%but
|
||||
%
|
||||
|
||||
\end{frame}
|
||||
|
||||
|
Loading…