My bib now a link --- cannot have several
versions of this it gets confusing Added a work so far on SFMEA... Might change the name FMMD to MFMEA
This commit is contained in:
parent
aa074ee773
commit
a05887fd0e
17
mybib.bib
17
mybib.bib
@ -1,3 +1,20 @@
|
||||
Model-driven automated software FMEA Proceedings - Annual
|
||||
Snooke, N.
|
||||
Comput. Sci. Dept., Aberystwyth Univ., Aberystwyth, UK
|
||||
|
||||
@ARTICLE{embedsfmea,
|
||||
AUTHOR = "Peter L. Goddard",
|
||||
TITLE = "Validating The Safety of Embedded Real-Time Control Systems using FMEA",
|
||||
JOURNAL = "Reliability and Maintainability Symposium (RAMS), 1993 Proceedings - Annual",
|
||||
YEAR = "1993"
|
||||
}
|
||||
|
||||
@ARTICLE{modelsfmea,
|
||||
AUTHOR = "Snooke, N",
|
||||
TITLE = "Model-driven automated software FMEA",
|
||||
JOURNAL = "Reliability and Maintainability Symposium (RAMS), 2011 Proceedings - Annual",
|
||||
YEAR = "2011"
|
||||
}
|
||||
|
||||
|
||||
@ARTICLE{sfmeaa,
|
||||
|
@ -69,6 +69,7 @@
|
||||
\newcommand{\dc}{derived~component}
|
||||
\newcommand{\dcs}{derived~components}
|
||||
\newcommand{\bc}{base~component}
|
||||
\newcommand{\FMMD}{ModularFMEA}
|
||||
\newcommand{\bcs}{base~components}
|
||||
\newcommand{\irl}{in real life}
|
||||
\newcommand{\enc}{\ensuremath{\stackrel{enc}{\longrightarrow}}}
|
||||
@ -209,7 +210,7 @@ failure modes to fix.
|
||||
|
||||
Failure Mode Effects and Diagnostics Analysis, is FMEA peformed to
|
||||
determine a statistical level of safety.
|
||||
This is associated with SIL classification levels~\cite{en61508}~\cite{en61511}.
|
||||
This is associated with Safety Integrity Levels (SIL)~\cite{en61508}~\cite{en61511} classification.
|
||||
|
||||
FMMD is a modularisation of FMEA and can produce failure~mode models that can be used in
|
||||
all the above variants of FMEA.
|
||||
@ -222,7 +223,11 @@ FMEA on the software in isolation~\cite{procsfmea}.
|
||||
Some work has been performed using databases
|
||||
to track the relationships between variables
|
||||
and system failure modes~\cite{procsfmeadb}, and work has been performed to
|
||||
introduce automation into the FMEA process~\cite{appswfmea}.
|
||||
introduce automation into the FMEA process~\cite{appswfmea} and code analysis
|
||||
automation~\cite{modelsfmea}. Although the SFMEA and hardware FMEAs are performed separately
|
||||
some schools of thought aim for FTA~\cite{nasafta}~\cite{nucfta} (top down - deductive) and FMEA (bottom-up inductive)
|
||||
to be performed on the same system to provide insight into the
|
||||
software hardware/interface~\cite{embedsfmea}.
|
||||
|
||||
\subsection{Current FMEA techniques are not suitable for software}
|
||||
|
||||
@ -957,7 +962,8 @@ of this paper.
|
||||
\end{itemize}
|
||||
%\today
|
||||
%
|
||||
{ %\tiny %\footnotesize
|
||||
{ %\tiny %
|
||||
\footnotesize
|
||||
\bibliographystyle{plain}
|
||||
\bibliography{vmgbibliography,mybib}
|
||||
}
|
||||
|
Loading…
Reference in New Issue
Block a user