@ -406,6 +406,16 @@ into the same failure mode model.
|
||||
%\clearpage
|
||||
\section{Conclusion}
|
||||
|
||||
The derived component representing the {\ft} reader
|
||||
in software shows that by taking a modular approach, we can integrate
|
||||
software and electro-mechanical FMEA models.
|
||||
|
||||
The unsolved symptoms, or unobservable errors, could be addressed
|
||||
by another software function to read other known signals
|
||||
via the MUX (i.e. voltage references). This strategy would
|
||||
detect ADC STUCK AT and MUX FAIL failure modes.
|
||||
|
||||
Detailing this however, is beyond the scope and page-count of this paper.
|
||||
%Its solved. Hoooo-ray !!!!!!!!!!!!!!!!!!!!!!!!
|
||||
|
||||
|
||||
|