@ -405,7 +405,17 @@ into the same failure mode model.
|
|||||||
|
|
||||||
%\clearpage
|
%\clearpage
|
||||||
\section{Conclusion}
|
\section{Conclusion}
|
||||||
|
|
||||||
|
The derived component representing the {\ft} reader
|
||||||
|
in software shows that by taking a modular approach, we can integrate
|
||||||
|
software and electro-mechanical FMEA models.
|
||||||
|
|
||||||
|
The unsolved symptoms, or unobservable errors, could be addressed
|
||||||
|
by another software function to read other known signals
|
||||||
|
via the MUX (i.e. voltage references). This strategy would
|
||||||
|
detect ADC STUCK AT and MUX FAIL failure modes.
|
||||||
|
|
||||||
|
Detailing this however, is beyond the scope and page-count of this paper.
|
||||||
%Its solved. Hoooo-ray !!!!!!!!!!!!!!!!!!!!!!!!
|
%Its solved. Hoooo-ray !!!!!!!!!!!!!!!!!!!!!!!!
|
||||||
|
|
||||||
|
|
||||||
|