tidying...

This commit is contained in:
Robin Clark 2011-11-19 12:10:28 +00:00
parent cbb1ce41a9
commit 645374c7b0

View File

@ -1136,10 +1136,12 @@ Where $L$ represents the number of levels in the FMMD hierarchy,
$|\xi|$ represents the number of functional groups on the level
and $H$ represents an FMMD hierarchy,
we overload the comparison complexity equation thus:
$$
%$$
\begin{equation}
\label{eqn:gf}
CC(H) = \sum_{\xi=0}^{L} \sum_{j=1}^{|\xi|} CC({G}_{j}^{\xi}).
$$
%$$
\end{equation}
\pagebreak[4]
@ -1165,7 +1167,7 @@ rigorous checking feasible.
\pagebreak[4]
\subsection{Using the concept of Complexity Comparison to compare RFMEA with FMMD}
%\subsection{Using the concept of Complexity Comparison to compare RFMEA with FMMD}
\begin{figure}
\centering
@ -1190,7 +1192,7 @@ to represent the number of checks to make.
Consider $k$ to be the number of components in a {\fg} (i.e. $k=|{\FG}|$),
$f$ is the number of failure modes per component (i.e. $f=|fm(c)|$), and
$L$ to be the number of levels in the hierarchy of an FMMD analysis.
We can represent the number of failure scenarios to check in an FMMD
We can represent the number of failure scenarios to check in a (fixed parameter for $|{\FG}|$ and $|fm(c_i)|$) FMMD hierarchy
with equation~\ref{eqn:anscen}.
\begin{equation}