Morning edit
This commit is contained in:
parent
c7599d4092
commit
5628f58daf
@ -163,7 +163,7 @@ and let the set of all possible failure modes be $\mathcal{F}$.
|
|||||||
We can define a function $fm$
|
We can define a function $fm$
|
||||||
|
|
||||||
\begin{equation}
|
\begin{equation}
|
||||||
fm : \mathcal{C} \mapsto \mathcal{P}\mathcal{F}
|
fm : \mathcal{C} \rightarrow \mathcal{P}\mathcal{F}
|
||||||
\end{equation}
|
\end{equation}
|
||||||
|
|
||||||
defined by, where C is a component and F is a set of failure modes.
|
defined by, where C is a component and F is a set of failure modes.
|
||||||
|
@ -5,6 +5,12 @@
|
|||||||
|
|
||||||
% $Id: mybib.bib,v 1.3 2009/11/28 20:05:52 robin Exp $
|
% $Id: mybib.bib,v 1.3 2009/11/28 20:05:52 robin Exp $
|
||||||
|
|
||||||
|
@ARTICLE{caninauto,
|
||||||
|
AUTHOR = "H. Zeltwanger",
|
||||||
|
TITLE = "Single Processor implementation of the CANopen Safety Protocol",
|
||||||
|
JOURNAL = "CAN in Automation (CiA)",
|
||||||
|
YEAR = "2008"
|
||||||
|
}
|
||||||
|
|
||||||
@ARTICLE{valueoflife,
|
@ARTICLE{valueoflife,
|
||||||
AUTHOR = "W.K. Viscusi",
|
AUTHOR = "W.K. Viscusi",
|
||||||
|
@ -48,7 +48,7 @@ For the Brewery, safety is of the highest importance.
|
|||||||
For the Nuclear power station
|
For the Nuclear power station
|
||||||
|
|
||||||
|
|
||||||
\section{Terms and Concepts in // Safety Critical Engineering}
|
\section{Terms and Concepts in \\ Safety Critical Engineering}
|
||||||
|
|
||||||
\subsection{Safety Relevant Data Object}
|
\subsection{Safety Relevant Data Object}
|
||||||
A Safety Relevant Data Object (SRDO)\cite{caninauto}, is a data structure describing the status of
|
A Safety Relevant Data Object (SRDO)\cite{caninauto}, is a data structure describing the status of
|
||||||
@ -58,8 +58,8 @@ the measure neutron flux.
|
|||||||
\subsection{Safety relevant Object Validation Time}
|
\subsection{Safety relevant Object Validation Time}
|
||||||
Safety times can be given for SRDO's; these are termed Safety Related Object Validation Times (SROVT's)\cite{caninauto}. For instance were
|
Safety times can be given for SRDO's; these are termed Safety Related Object Validation Times (SROVT's)\cite{caninauto}. For instance were
|
||||||
a flame to fail in operation in a gas burner
|
a flame to fail in operation in a gas burner
|
||||||
standards state that the gas may not continue to be fed into the
|
standards state \cite{en298} that the gas may not continue to be fed into the
|
||||||
furnace for more than three seconds \cite{en298}.
|
furnace for more than three seconds.
|
||||||
We can say that the SROVT for a flame signal in a gas burner is 3 seconds.
|
We can say that the SROVT for a flame signal in a gas burner is 3 seconds.
|
||||||
\subsection{Single and Double Failure Modes}
|
\subsection{Single and Double Failure Modes}
|
||||||
A Safety critical system must self check within the relevant SROVT's.
|
A Safety critical system must self check within the relevant SROVT's.
|
||||||
|