forgot to commit from last time
This commit is contained in:
parent
6636f108d0
commit
20565773ae
24
mybib.bib
24
mybib.bib
@ -767,7 +767,31 @@ strength of materials, the causes of boiler explosions",
|
||||
year = 2009
|
||||
}
|
||||
|
||||
@inproceedings{Bishop:2010:ONT:1886301.1886325,
|
||||
author = {Bishop, Peter and Cyra, Lukasz},
|
||||
title = {Overcoming non-determinism in testing smart devices: a case study},
|
||||
booktitle = {Proceedings of the 29th international conference on Computer safety, reliability, and security},
|
||||
series = {SAFECOMP'10},
|
||||
year = {2010},
|
||||
isbn = {3-642-15650-9, 978-3-642-15650-2},
|
||||
location = {Vienna, Austria},
|
||||
pages = {237--250},
|
||||
numpages = {14},
|
||||
url = {http://dl.acm.org.ezproxy.brighton.ac.uk/citation.cfm?id=1886301.1886325},
|
||||
acmid = {1886325},
|
||||
publisher = {Springer-Verlag},
|
||||
address = {Berlin, Heidelberg},
|
||||
keywords = {non-determinism, safety, smart instruments, testing},
|
||||
}
|
||||
|
||||
@article{smartinstruments,
|
||||
title="Smart instruments in safety instrumented systems: http://www.isa.org/InTechTemplate.cfm?template=/ContentManagement/ContentDisplay.cfm$\&$ContentID=77994",
|
||||
author={Tom S nobes},
|
||||
year={2009},
|
||||
biburl="http://www.isa.org/InTechTemplate.cfm?template=/ContentManagement/ContentDisplay.cfm\&ContentID=77994",
|
||||
}
|
||||
|
||||
|
||||
@PHDTHESIS{garrett,
|
||||
AUTHOR = "Chris Garrett",
|
||||
TITLE = "Functional diagnosis strategies for analog systems using heuristic programming techniques",
|
||||
|
@ -194,9 +194,12 @@ only requires that the failure mode OPEN be considered for FMEA analysis.
|
||||
%
|
||||
For resistor types not specifically listed in EN298, the failure modes
|
||||
are considered to be either OPEN or SHORT.
|
||||
%
|
||||
The reason that parameter change is not considered for resistors chosen for an EN298 compliant system, is that they must be must be {\em downrated}.
|
||||
That is to say the power and voltage ratings of components must be calculated
|
||||
for maximum possible exposure, with a 40\% margin of error. This drastically reduces the probability
|
||||
for maximum possible exposure, with a 40\% margin of error.
|
||||
%
|
||||
This drastically reduces the probability
|
||||
that the resistors will be overloaded,
|
||||
and thus subject to drift/parameter change.
|
||||
|
||||
@ -567,8 +570,12 @@ we can hop from module to module eliminating working modules, until we find the
|
||||
failure.
|
||||
|
||||
|
||||
FMEA is a theoretical discipline. It would be very unusual to build a circuit and then simulate
|
||||
component failure modes. This would be very time consuming as it would involve building a circuit for each component {\fm} in the system.
|
||||
FMEA is a theoretical discipline.
|
||||
%
|
||||
It would be very unusual to build a circuit and then simulate
|
||||
component failure modes.
|
||||
%
|
||||
This would be time consuming as it would involve building a circuit for each component {\fm} in the system.
|
||||
%
|
||||
We cannot, as with fault finding, verify modules along the signal path for correct behaviour
|
||||
and eliminate them from the investigation.
|
||||
@ -580,7 +587,7 @@ Too much and the task becomes impossible due to time/labour constraints.
|
||||
Too little and the analysis could become meaningless because it misses
|
||||
potential system failures.
|
||||
%
|
||||
For a more complete analysis we should perhaps, examine each component {\fm} along the complete signal path,
|
||||
For a more complete analysis we should perhaps examine each component {\fm} along the complete signal path,
|
||||
forwards and backwards from the placement
|
||||
of the component exhibiting the {\fm} under investigation.
|
||||
%
|
||||
@ -603,7 +610,7 @@ The concept of the unacceptability of a single component failure causing a syste
|
||||
is an important and easily understood measurement of safety.
|
||||
%
|
||||
It is easy to calculate
|
||||
because we can usually find Mean Time to Failure (MTTF) statistics for commonly used components.
|
||||
because we can usually find Mean Time to Failure (MTTF) statistics~\cite{fmd91,mil1991} for commonly used components.
|
||||
%
|
||||
Also, used in the design phase of a project, FMEA is a useful tool
|
||||
for discovering potential failure scenarios~\cite{1778436820050601}.
|
||||
@ -631,8 +638,8 @@ did not link this failure to the catastrophic failure of the spacecraft~\cite{ch
|
||||
This was not a failure in the objective reasoning, but more of the subjective, or the context in which the leak occurred.
|
||||
%
|
||||
FMEA is less useful for determining events for multiple
|
||||
simultaneous\footnote{Multiple simultaneous failures are taken to mean failures that occur within the same detection period.}
|
||||
failures.
|
||||
simultaneous
|
||||
failures\footnote{Multiple simultaneous failures are taken to mean failures that occur within the same detection period.}.
|
||||
%
|
||||
Work has been performed using component failure statistics to
|
||||
offer the more likely multiple failures~\cite{FMEAmultiple653556} for analysis.
|
||||
@ -668,7 +675,7 @@ Modern electronic components, are generally very reliable, and the systems built
|
||||
are thus very reliable too. Reliable field data on failures will, therefore be sparse.
|
||||
Should we wish to prove a continuous demand system for say ${10}^{-7}$ failures\footnote{${10}^{-7}$ failures per hour of operation is the
|
||||
threshold for S.I.L. 3 reliability~\cite{en61508}. Failure rates are normally measured per $10^9$ hours of operation
|
||||
and are know as Failure in Time (FIT) values. The maximum FIT values for a SIL 3 system is therefore 100.}
|
||||
and are known as Failure in Time (FIT) values. The maximum FIT values for a SIL 3 system is therefore 100.}
|
||||
per hour of operation, even with 1000 correctly monitored units in the field
|
||||
we could only expect one failure per ten thousand hours (a little over one a year).
|
||||
It would be utterly impractical to get statistically significant data for equipment
|
||||
@ -725,8 +732,10 @@ methodologies.
|
||||
|
||||
FMEA for a safety critical certification~\cite{en298,en61508} will have to be applied
|
||||
to all known failure modes of all components within a system.
|
||||
%
|
||||
FMEA does not define or specify the scope of the investigation of each component failure mode.
|
||||
Should we follow the signal path, and all components we encounter along that, or should the scope be wider?
|
||||
%
|
||||
If we were to examine the effect of a component {\fm} against all other components
|
||||
in a system, this could be said to be exhaustive analysis.
|
||||
|
||||
@ -779,7 +788,7 @@ we rely on experts in the system under investigation
|
||||
to perform a meaningful FMEA analysis.
|
||||
%
|
||||
In practise these experts have to select the areas they see as most critical for detailed FMEA analysis:
|
||||
its is usually impossible to perform a detail level of analysis on all component {\fms}
|
||||
it is usually impossible to perform a detail level of analysis on all component {\fms}
|
||||
on anything but a non-trivial system.
|
||||
|
||||
\subsection{Component Tolerance}
|
||||
@ -787,6 +796,7 @@ on anything but a non-trivial system.
|
||||
Component tolerances may need considered when determining if a component has failed.
|
||||
Calculations for acceptable ranges to determine failure or acceptable conditions
|
||||
must be made where appropriate.
|
||||
%
|
||||
An example of component tolerance considered for FMEA
|
||||
is given in section~\ref{sec:resistortolerance}.
|
||||
|
||||
@ -795,7 +805,7 @@ is given in section~\ref{sec:resistortolerance}.
|
||||
\paragraph{Five main Variants of FMEA}
|
||||
\begin{itemize}
|
||||
\item \textbf{PFMEA - Production} Emphasis on cost reduction and product improvement;
|
||||
\item \textbf{FMECA - Criticality} Emphasis on minimising the effect of critial systems failing; % Military/Space
|
||||
\item \textbf{FMECA - Criticality} Emphasis on minimising the effect of critical systems failing; % Military/Space
|
||||
\item \textbf{FMEDA - Statistical safety} Statistical analysis giving Safety Integrity Levels;
|
||||
\item \textbf{DFMEA - Design or static/theoretical} Approval of safety critical systems using FMEA and single or double failure prevention;% EN298/EN230/UL1998
|
||||
\item \textbf{SFMEA - Software FMEA --- only used in highly critical systems at present}
|
||||
|
@ -15,8 +15,9 @@ This analysis philosophy has not changed since FMEA was first used.
|
||||
|
||||
|
||||
\subsection{FMEA does not support modularity.}
|
||||
It is a common practise in the process control industry to buy in sub-systems, typically sensors and actuators connected to an industrially hardened computer bus, i.e. CANbus~\cite{can,canspec}, modbus~\cite{modbus} etc.
|
||||
Most sensor systems now are `smart', that is to say, they contain programmatic elements
|
||||
It is a common practise in the process control industry to buy in sub-systems,
|
||||
typically sensors and actuators connected to an industrially hardened computer bus, i.e. CANbus~\cite{can,canspec}, modbus~\cite{modbus} etc.
|
||||
Most sensor systems now are `smart'~\cite{smartinstruments}, that is to say, they contain programmatic elements
|
||||
even if their outputs are %they supply
|
||||
analogue signals. For instance a liquid level sensor that
|
||||
supplies a {\ft} output, would have been typically have been implemented
|
||||
@ -120,6 +121,11 @@ and measurements of physical characteristics of materials and machinery.
|
||||
For highly critical systems i.e. the nuclear industry, the instruments used to perform these measurements, must be analysed for
|
||||
FMEA, to ensure that failure modes within the instrument cannot lead to invalid measurements.
|
||||
%
|
||||
Some work has been performed to offer black~box---or functional testing---of these instruments instead of
|
||||
static analysis~\cite{Bishop:2010:ONT:1886301.1886325}.
|
||||
However, black box testing of smart instruments is
|
||||
yet to be a an approved method of validation.
|
||||
%
|
||||
Most modern instruments now use highly integrated electronics coupled to micro-controllers, which read and filter the measurements,
|
||||
and interface to an LCD readout.
|
||||
%
|
||||
@ -128,7 +134,8 @@ the design of instruments.
|
||||
%
|
||||
While noting that being more modern, these instruments are likely to be more reliable and
|
||||
accurate than the analogue instruments in use some twenty years ago but this cannot be validated
|
||||
to a high level of reliability by traditional FMEA.
|
||||
to a high level of reliability. This remains an unsolved problem for the industries dealing with highly safety critical
|
||||
systems. %by traditional FMEA.
|
||||
|
||||
\subsection{Distributed real time systems}
|
||||
|
||||
|
Loading…