forgot to commit from work
This commit is contained in:
parent
db0ff368e8
commit
080e043506
11
mybib.bib
11
mybib.bib
@ -29,6 +29,17 @@
|
||||
YEAR = "2012"
|
||||
}
|
||||
|
||||
@INPROCEEDINGS{sfmeainterface,
|
||||
author={Ozarin, N.W.},
|
||||
booktitle={Reliability and Maintainability Symposium, 2009. RAMS 2009. Annual}, title={Applying software failure modes and effects analysis to interfaces},
|
||||
year={2009},
|
||||
month={jan.},
|
||||
volume={},
|
||||
number={},
|
||||
pages={533 -538},
|
||||
keywords={mission-critical system;safety-critical system;software failure mode and effect analysis;software variable;system recovery;},
|
||||
doi={10.1109/RAMS.2009.4914732},
|
||||
ISSN={0149-144X},}
|
||||
|
||||
@ARTICLE{sfmea,
|
||||
AUTHOR = "Chris Price, Neal Snooke",
|
||||
|
@ -121,7 +121,7 @@ failure mode of the component or sub-system}}}
|
||||
% {-\baslineskip}
|
||||
% {0.5\baselineskip}
|
||||
% {\normalfont\normalsize\itshape}}%
|
||||
\linespread{0.95}
|
||||
\linespread{0.94}
|
||||
|
||||
\begin{document}
|
||||
%\pagestyle{fancy}
|
||||
@ -734,10 +734,24 @@ the base components in this design.
|
||||
We now apply FMMD starting with the hardware.
|
||||
|
||||
|
||||
\subsection{FMMD Process}
|
||||
\subsection{FMMD Process --- {\ft} programmatic value implementation.}
|
||||
|
||||
\begin{figure}[h]
|
||||
\centering
|
||||
\includegraphics[width=150pt,keepaspectratio=true]{./hd.png}
|
||||
% hd.png: 416x381 pixel, 72dpi, 14.68x13.44 cm, bb=0 0 416 381
|
||||
\caption{FMMD Hierarchy for {\ft} input}
|
||||
\label{fig:hd}
|
||||
\end{figure}
|
||||
|
||||
We analyse the {\ft} to programmatic value implementation in three stages using FMMD.
|
||||
We start with the hardware,
|
||||
add then each of the software functions.
|
||||
This forms the fault mode hierarchy represented in figure~\ref{fig:hd}.
|
||||
|
||||
\paragraph{Functional Group - Convert mA to Voltage - CMATV}
|
||||
|
||||
|
||||
This functional group contains the load resistor
|
||||
and the physical Analogue to Digital Converter (ADC).
|
||||
%
|
||||
@ -975,13 +989,7 @@ as a hierarchical diagram, see figure~\ref{fig:hd}.
|
||||
% \label{fig:hd}
|
||||
% \end{figure}
|
||||
|
||||
\begin{figure}[h]
|
||||
\centering
|
||||
\includegraphics[width=150pt,keepaspectratio=true]{./hd.png}
|
||||
% hd.png: 416x381 pixel, 72dpi, 14.68x13.44 cm, bb=0 0 416 381
|
||||
\caption{FMMD Hierarchy for {\ft} input}
|
||||
\label{fig:hd}
|
||||
\end{figure}
|
||||
|
||||
|
||||
|
||||
|
||||
@ -1036,7 +1044,7 @@ as a hierarchical diagram, see figure~\ref{fig:hd}.
|
||||
%\clearpage
|
||||
\section{Conclusion}
|
||||
%
|
||||
The FMMD method has been demonstrated, using an the industry stanbdard {\ft}
|
||||
The FMMD method has been demonstrated, using an the industry standard {\ft}
|
||||
input circuit and software.
|
||||
%
|
||||
The {\dc} representing the {\ft} reader
|
||||
@ -1069,7 +1077,7 @@ re-use this analysis for each {\ft} input in the system.
|
||||
%
|
||||
%A software specification for a hardware interface will concentrate on
|
||||
%how to interpret raw readings, or what signals to apply for actuators.
|
||||
Additionally, using FMMD we can determine a failure model for the hardware/software interface. % interface as well.
|
||||
Additionally, using FMMD we can determine a failure model for the hardware/software interface~\cite{sfmeainterface}. % interface as well.
|
||||
|
||||
%Its solved. Hoooo-ray !!!!!!!!!!!!!!!!!!!!!!!!
|
||||
|
||||
|